{"id":24859,"date":"2026-04-27T13:43:32","date_gmt":"2026-04-27T05:43:32","guid":{"rendered":"https:\/\/www.jxscmachine.com\/?post_type=new&#038;p=24859"},"modified":"2026-04-27T13:43:32","modified_gmt":"2026-04-27T05:43:32","slug":"how-to-perform-daily-maintenance-on-a-shaking-table","status":"publish","type":"new","link":"https:\/\/www.jxscmachine.com\/pt\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/","title":{"rendered":"How to Perform Daily Maintenance on a Shaking Table?"},"content":{"rendered":"<p><a href=\"https:\/\/www.jxscmachine.com\/pt\/separador-de-gravidade\/mesa-vibratoria-de-ouro\/\">Mesas de agita\u00e7\u00e3o<\/a> are workhorses in mineral processing, enduring constant vibration and abrasion. Without proper daily care, their efficiency drops rapidly while repair costs skyrocket.<\/p>\n<p><strong><b>Perform these five essential maintenance actions daily: inspect core components, replace worn headboard parts, check transmission systems, protect table surfaces, and follow proper shutdown procedures. This routine maintains over 95% mineral recovery rates and can extend your equipment&#8217;s lifespan by 3-5 years.<\/b><\/strong><\/p>\n<p>Regular maintenance might seem time-consuming, but it prevents costly breakdowns that could halt your entire operation. Let&#8217;s examine each critical maintenance area in detail.<\/p>\n<p>&nbsp;<\/p>\n<h2>What Are the Key Points for Daily Maintenance of Shaking Tables?<\/h2>\n<p>The shaking table&#8217;s daily beating requires focused attention on its most vulnerable areas. Neglecting even one component can start a chain reaction of failures.<\/p>\n<p><strong><b>Prioritize five maintenance zones: the deck surface (for cracks\/wear), headboard components (especially riffles), transmission system (belts\/bearings), protective surfaces, and post-operation cleaning. Spending 15-20 minutes daily on these prevents 80% of common failures.<\/b><\/strong><\/p>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_24862\" aria-describedby=\"caption-attachment-24862\" style=\"width: 449px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-24862\" src=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg\" alt=\"mesa de agita\u00e7\u00e3o\" width=\"449\" height=\"800\" srcset=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg 449w, https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3-7x12.jpg 7w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><\/a><figcaption id=\"caption-attachment-24862\" class=\"wp-caption-text\">mesa de agita\u00e7\u00e3o<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<h3>1. How to Inspect Core Components (Deck, headboard, rack)?<\/h3>\n<p>The deck&nbsp;bears the highest stress during mineral processing. Cracks or warping here directly impact separation quality.<\/p>\n<p><strong><b>Inspect bed surfaces for cracks daily using a flashlight. Check headboard alignment with a straightedge (tolerance &lt;2mm). Verify rack stability by testing for abnormal vibration (&gt;15% baseline requires adjustment).<\/b><\/strong><\/p>\n<p><strong><b>Core Component Maintenance Protocol<\/b><\/strong><\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><strong><b>Componente<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Inspection Method<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Acceptable Range<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Maintenance Action<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Deck<\/td>\n<td style=\"text-align: center;\">Visual\/tactile check<\/td>\n<td style=\"text-align: center;\">No visible cracks<\/td>\n<td style=\"text-align: center;\">Epoxy repair for a crack &lt; 10 cm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Headboard<\/td>\n<td style=\"text-align: center;\">Straightedge test<\/td>\n<td style=\"text-align: center;\">&lt;2mm deviation<\/td>\n<td style=\"text-align: center;\">Shim adjustment required<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Support rack<\/td>\n<td style=\"text-align: center;\">Vibration analysis<\/td>\n<td style=\"text-align: center;\">\u00b110% of baseline<\/td>\n<td style=\"text-align: center;\">Tighten bolts\/add dampeners<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><b>Critical signs needing immediate attention<\/b><\/strong><\/p>\n<ul>\n<li>Visible cracks in the bed surface<\/li>\n<li>Loose headboard mounting bolts<\/li>\n<li>Rust accumulating on support racks<\/li>\n<li>Uneven wear patterns on the bed surface<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>2. What Headboard Parts Need Frequent Replacement?<\/h3>\n<p>The headboard&#8217;s riffles and water channels experience severe abrasive wear during slurry processing.<\/p>\n<p><strong><b>Replace rubber riffles every 3-6 months in high-wear zones. Inspect water distribution channels daily for clogging. Use ceramic-coated components in high-impact areas to triple service life.<\/b><\/strong><\/p>\n<p><strong><b>Wear Part Replacement Schedule<\/b><\/strong><\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><strong><b>Part<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Material Options<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Lifespan<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Upgrade Benefits<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Riffles<\/td>\n<td style=\"text-align: center;\">Natural rubber<\/td>\n<td style=\"text-align: center;\">3-6 months<\/td>\n<td style=\"text-align: center;\">Lowest cost option<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Deck Liners<\/td>\n<td style=\"text-align: center;\">Poliuretano<\/td>\n<td style=\"text-align: center;\">6-12 months<\/td>\n<td style=\"text-align: center;\">2x the lifespan of rubber<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Water nozzles<\/td>\n<td style=\"text-align: center;\">Brass<\/td>\n<td style=\"text-align: center;\">1 year<\/td>\n<td style=\"text-align: center;\">Standard performance<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Feed Box<\/td>\n<td style=\"text-align: center;\">Ceramic<\/td>\n<td style=\"text-align: center;\">3+ years<\/td>\n<td style=\"text-align: center;\">Clog-resistant<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><b>Common mistakes to avoid<\/b><\/strong><\/p>\n<ul>\n<li>Using undersized replacement parts<\/li>\n<li>Ignoring early-stage riffle wear<\/li>\n<li>Not cleaning water channels after shifts<\/li>\n<li>Mixing different riffle materials<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>3. Why Check Transmission Components Daily?<\/h3>\n<p>Vibration mechanisms operate under constant heavy loads, with failures causing sudden production stops.<\/p>\n<p><strong><b>Measure drive belt tension weekly (deflection &lt;15mm). Grease bearings every 200 operating hours. Check motor couplings monthly for concentricity (&lt;0.1mm runout).<\/b><\/strong><\/p>\n<h4>Transmission Maintenance Checklist<\/h4>\n<ol>\n<li><b><\/b><strong><b>Drive System<\/b><\/strong><\/li>\n<\/ol>\n<ul>\n<li>Belt tension: 15-20N force = 10-15mm deflection<\/li>\n<li>Sheave alignment: &lt;1mm lateral variance<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><b><\/b><strong><b>Bearings<\/b><\/strong><\/li>\n<\/ol>\n<ul>\n<li>Temperature: &lt;70\u00b0C during operation<\/li>\n<li>Grease type: Lithium complex EP2<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><b><\/b><strong><b>Motor<\/b><\/strong><\/li>\n<\/ol>\n<ul>\n<li>Current draw: \u00b15% of nameplate rating<\/li>\n<li>Vibration: &lt;4.5mm\/s RMS<\/li>\n<\/ul>\n<p><strong><b>Warning signs<\/b><\/strong><\/p>\n<ul>\n<li>High-pitched squealing noises<\/li>\n<li>Excessive belt dust accumulation<\/li>\n<li>Hot spots on bearing housings<\/li>\n<li>Irregular vibration patterns<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>4. How to Protect Table Surfaces Effectively?<\/h3>\n<p>The condition of the separation surface determines mineral recovery rates more than any other factor.<\/p>\n<p><strong><b>Apply protective coating quarterly (epoxy or polyurethane). Clean spillage immediately to prevent corrosion. Use polyethylene wear mats in high-traffic areas.<\/b><\/strong><\/p>\n<p><strong><b>Surface Protection Methods<\/b><\/strong><\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" width=\"26.3200%\"><strong><b>Threat<\/b><\/strong><\/td>\n<td style=\"text-align: center;\" width=\"44.2400%\"><strong><b>Protection Method<\/b><\/strong><\/td>\n<td style=\"text-align: center;\" width=\"29.4200%\"><strong><b>Frequ\u00eancia<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"26.3200%\">Abrasion<\/td>\n<td style=\"text-align: center;\" width=\"44.2400%\">Ceramic tiles<\/td>\n<td style=\"text-align: center;\" width=\"29.4200%\">Permanent<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"26.3200%\">Corrosion<\/td>\n<td style=\"text-align: center;\" width=\"44.2400%\">Epoxy coating<\/td>\n<td style=\"text-align: center;\" width=\"29.4200%\">6 months<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"26.3200%\">Impact<\/td>\n<td style=\"text-align: center;\" width=\"44.2400%\">Rubber matting<\/td>\n<td style=\"text-align: center;\" width=\"29.4200%\">Cont\u00ednuo<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"26.3200%\">Chemical<\/td>\n<td style=\"text-align: center;\" width=\"44.2400%\">Acid-resistant paint<\/td>\n<td style=\"text-align: center;\" width=\"29.4200%\">Annual<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><b>Best practices<\/b><\/strong><\/p>\n<ul>\n<li>Always keep the surface wet during operation<\/li>\n<li>Never use metal tools on the table surface<\/li>\n<li>Store tables covered when not in use<\/li>\n<li>Rinse thoroughly after processing acidic ores<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>5. What Post-Operation Procedures Are Essential?<\/h3>\n<p>Proper shutdown routines prevent 60% of common shaking table failures according to industry studies.<\/p>\n<p><strong><b>Complete these steps after each shift: Flush water channels, lubricate moving parts, secure loose components, and document equipment condition in maintenance logs.<\/b><\/strong><\/p>\n<h4>End-of-Day Maintenance Protocol<\/h4>\n<ol>\n<li><b><\/b><strong><b>Cleaning<\/b><\/strong><\/li>\n<\/ol>\n<ul>\n<li>Flush slurry lines for 5 minutes<\/li>\n<li>Remove all concentrate buildup<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><b><\/b><strong><b>Lubrifica\u00e7\u00e3o<\/b><\/strong><\/li>\n<\/ol>\n<ul>\n<li>Apply grease to all zerks<\/li>\n<li>Oil adjustment mechanisms<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><b><\/b><strong><b>Inspection<\/b><\/strong><\/li>\n<\/ol>\n<ul>\n<li>Torque-check critical bolts<\/li>\n<li>Test emergency stops<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><b><\/b><strong><b>Documenta\u00e7\u00e3o<\/b><\/strong><\/li>\n<\/ol>\n<ul>\n<li>Record vibration measurements<\/li>\n<li>Note any abnormalities<\/li>\n<\/ul>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\">\n<p><figure id=\"attachment_24861\" aria-describedby=\"caption-attachment-24861\" style=\"width: 450px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-24861\" src=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-2.jpg\" alt=\"mesa de agita\u00e7\u00e3o\" width=\"450\" height=\"800\" srcset=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-2.jpg 450w, https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-2-7x12.jpg 7w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/a><figcaption id=\"caption-attachment-24861\" class=\"wp-caption-text\">mesa de agita\u00e7\u00e3o<\/figcaption><\/figure><\/td>\n<td style=\"width: 50%;\">\n<p><figure id=\"attachment_24860\" aria-describedby=\"caption-attachment-24860\" style=\"width: 450px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-24860\" src=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-1.jpg\" alt=\"mesa de agita\u00e7\u00e3o\" width=\"450\" height=\"800\" srcset=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-1.jpg 450w, https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-1-7x12.jpg 7w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/a><figcaption id=\"caption-attachment-24860\" class=\"wp-caption-text\">mesa de agita\u00e7\u00e3o<\/figcaption><\/figure><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h1><strong><b>&nbsp;<\/b><\/strong><\/h1>\n<h2>What Are The General Daily Maintenance Tips for Most Shaking Tables?<\/h2>\n<p>While specific models vary, these universal practices apply to nearly all shaking tables.<strong><b>&nbsp;Always start with visual inspections before the operation. Keep detailed maintenance records. Train multiple staff on proper procedures. Schedule professional servicing annually.<\/b><\/strong><\/p>\n<p>&nbsp;<\/p>\n<h3>Cleaning and Maintenance<\/h3>\n<ul>\n<li>After each use, wipe the inner and outer surfaces of the equipment with a soft, damp cloth to remove dust, liquid, or culture medium residue.<\/li>\n<li>Regularly clean removable parts such as internal trays and clamps. Disinfect with 75% alcohol or a neutral detergent to avoid cross-contamination.<\/li>\n<li>Avoid the motor, vents, and control panel during cleaning to prevent water or dust from entering core components.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Lubrication Management<\/h3>\n<ul>\n<li>Add dedicated grease (silicone-based or calcium-sodium-based lubricant recommended) to moving parts such as bearings, belts, and guide rails every 3\u20136 months.<\/li>\n<li>Change the engine oil in the shaking table transmission box every 1\u20132 months, ensuring the oil level is above the oil pump position.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Tightening Check<\/h3>\n<ul>\n<li>Check the base, frame, and fixing bolts for looseness monthly. Tighten them promptly to prevent damage to components due to vibration.<\/li>\n<li>Check the clamp screws, springs, etc., for looseness.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Environmental Control<\/h3>\n<ul>\n<li>The equipment should be placed on a flat, sturdy, and well-ventilated surface, at least 30 cm away from walls on all sides.<\/li>\n<li>Avoid direct sunlight, rain, high temperature, and humidity (relative humidity \u226460% recommended), or environments with strong corrosive gases.<\/li>\n<li>Indoor use is preferred to prevent surface deformation or metal corrosion.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Electrical and Safety<\/h3>\n<ul>\n<li>Regularly check the power cord and plug for aging or damage, and ensure reliable grounding.<\/li>\n<li>If leakage, abnormal noise, overheating, or odor is detected, immediately disconnect the power and contact a professional.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Supplementary Maintenance Points by Shaking Table Type<\/h3>\n<p>Different shaking table designs have unique maintenance needs you shouldn&#8217;t overlook.<\/p>\n<p><strong><b>Conventional vs Modern Shaking Tables<\/b><\/strong><\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><strong><b>Maintenance Aspect<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Conventional Tables<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>Modern Tables<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Deck inspection<\/td>\n<td style=\"text-align: center;\">Daily visual check<\/td>\n<td style=\"text-align: center;\">Automated monitoring systems<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Bearing service<\/td>\n<td style=\"text-align: center;\">Manual greasing<\/td>\n<td style=\"text-align: center;\">Sealed bearings<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Adjustment<\/td>\n<td style=\"text-align: center;\">Manual screws<\/td>\n<td style=\"text-align: center;\">Hydraulic\/pneumatic<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Conclus\u00e3o<\/h2>\n<p>Consistent daily maintenance keeps shaking tables running at peak efficiency through systematic inspection of five critical areas: structural components, wear parts, transmission systems, surfaces, and proper shutdown procedures. This disciplined approach prevents costly downtime while maintaining optimal mineral recovery performance year after year.<\/p>","protected":false},"excerpt":{"rendered":"<p>Shaking tables are workhorses in mineral processing, enduring constant vibration and abrasion. Without proper daily care, their efficiency drops rapidly while repair costs skyrocket. Perform these five essential maintenance actions daily: inspect core components, replace worn headboard parts, check transmission systems, protect table surfaces, and follow proper shutdown procedures. This routine maintains over 95% mineral &hellip; <a href=\"https:\/\/www.jxscmachine.com\/pt\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/\" class=\"more-link\">Continuar a ler <span class=\"screen-reader-text\">How to Perform Daily Maintenance on a Shaking Table?<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":24862,"parent":0,"menu_order":8,"comment_status":"closed","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"ngg_post_thumbnail":0,"footnotes":""},"categories":[],"tags":[],"class_list":["post-24859","new","type-new","status-publish","format-standard","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Perform Daily Maintenance on a Shaking Table? - JXSC Machine<\/title>\n<meta name=\"description\" content=\"Regular maintenance can maintain a mineral recovery rate of over 95% and extend the service life of the shaking table by 3 to 5 years.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jxscmachine.com\/pt\/novo\/how-to-perform-daily-maintenance-on-a-shaking-table\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Perform Daily Maintenance on a Shaking Table? - JXSC Machine\" \/>\n<meta property=\"og:description\" content=\"Regular maintenance can maintain a mineral recovery rate of over 95% and extend the service life of the shaking table by 3 to 5 years.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jxscmachine.com\/pt\/novo\/how-to-perform-daily-maintenance-on-a-shaking-table\/\" \/>\n<meta property=\"og:site_name\" content=\"JXSC Machine\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"449\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/\",\"url\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/\",\"name\":\"How to Perform Daily Maintenance on a Shaking Table? - JXSC Machine\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jxscmachine.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/shaking-table-3.jpg\",\"datePublished\":\"2026-04-27T05:43:32+00:00\",\"description\":\"Regular maintenance can maintain a mineral recovery rate of over 95% and extend the service life of the shaking table by 3 to 5 years.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.jxscmachine.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/shaking-table-3.jpg\",\"contentUrl\":\"https:\\\/\\\/www.jxscmachine.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/shaking-table-3.jpg\",\"width\":449,\"height\":800,\"caption\":\"shaking table\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/how-to-perform-daily-maintenance-on-a-shaking-table\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.jxscmachine.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/www.jxscmachine.com\\\/new\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How to Perform Daily Maintenance on a Shaking Table?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.jxscmachine.com\\\/#website\",\"url\":\"https:\\\/\\\/www.jxscmachine.com\\\/\",\"name\":\"JXSC Machine\",\"description\":\"40+ Years&#039; Mineral Separating Equipment Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.jxscmachine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Perform Daily Maintenance on a Shaking Table? - JXSC Machine","description":"Regular maintenance can maintain a mineral recovery rate of over 95% and extend the service life of the shaking table by 3 to 5 years.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jxscmachine.com\/pt\/novo\/how-to-perform-daily-maintenance-on-a-shaking-table\/","og_locale":"pt_PT","og_type":"article","og_title":"How to Perform Daily Maintenance on a Shaking Table? - JXSC Machine","og_description":"Regular maintenance can maintain a mineral recovery rate of over 95% and extend the service life of the shaking table by 3 to 5 years.","og_url":"https:\/\/www.jxscmachine.com\/pt\/novo\/how-to-perform-daily-maintenance-on-a-shaking-table\/","og_site_name":"JXSC Machine","og_image":[{"width":449,"height":800,"url":"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo estimado de leitura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/","url":"https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/","name":"How to Perform Daily Maintenance on a Shaking Table? - JXSC Machine","isPartOf":{"@id":"https:\/\/www.jxscmachine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/#primaryimage"},"image":{"@id":"https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg","datePublished":"2026-04-27T05:43:32+00:00","description":"Regular maintenance can maintain a mineral recovery rate of over 95% and extend the service life of the shaking table by 3 to 5 years.","breadcrumb":{"@id":"https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/#primaryimage","url":"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg","contentUrl":"https:\/\/www.jxscmachine.com\/wp-content\/uploads\/2026\/04\/shaking-table-3.jpg","width":449,"height":800,"caption":"shaking table"},{"@type":"BreadcrumbList","@id":"https:\/\/www.jxscmachine.com\/new\/how-to-perform-daily-maintenance-on-a-shaking-table\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.jxscmachine.com\/"},{"@type":"ListItem","position":2,"name":"News","item":"https:\/\/www.jxscmachine.com\/new\/"},{"@type":"ListItem","position":3,"name":"How to Perform Daily Maintenance on a Shaking Table?"}]},{"@type":"WebSite","@id":"https:\/\/www.jxscmachine.com\/#website","url":"https:\/\/www.jxscmachine.com\/","name":"M\u00e1quina JXSC","description":"Mais de 40 anos como fabricante de equipamentos de separa\u00e7\u00e3o de minerais","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jxscmachine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"}]}},"_links":{"self":[{"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/new\/24859","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/new"}],"about":[{"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/types\/new"}],"author":[{"embeddable":true,"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/comments?post=24859"}],"version-history":[{"count":0,"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/new\/24859\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/media\/24862"}],"wp:attachment":[{"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/media?parent=24859"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/categories?post=24859"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jxscmachine.com\/pt\/wp-json\/wp\/v2\/tags?post=24859"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}